Fujikura Ltd.

  1. Home
  2. Products
  3. FPM Series(Gauge)

PRODUCTS

FPM Series(Gauge)

 

Contact us here for inquiries.
contact us

Features

  • Dual-in-line package(DIP)
  • Weight : 1.1grams

Ordering Information

 

Measurable pressure range(kPa) Part number
-13.79~13.79 FPM-02PG FPM-02PGR
-34.47~34.47 FPM-05PG FPM-05PGR
-48.26~48.26 FPM-07PG FPM-07PGR
-98.07~103.4 FPM-15PG FPM-15PGR
-98.07~206.8 FPM-30PG FPM-30PGR
-98.07~344.7 FPM-50PG FPM-50PGR
-98.07~482.6 FPM-70PG FPM-70PGR
-98.07~827.4 FPM-120PG FPM-120PGR

Specifications

Model 02PG 05PG 07PG 15PG 30PG 50PG 70PG 120PG Unit
Recommended operating conditions
Pressure type Gauge pressure -
Rated pressure 13.79 34.47 48.26 103.4 206.8 344.7 482.6 827.4 kPa
Measurable pressure range -13.79
~13.79
-34.47
~34.47
-48.26
~48.26
-98.07
~103.4
-98.07
~206.8
-98.07
~344.7
-98.07
~482.6
-98.07
~827.4
kPa
Temperature range 0~50 °C
Pressure media Non-corrosive gases only(No liquid) -
Excitation current(Constant) 1.5 mADC
Absolute maximum rating
Maximum load pressure Twice of rated pressure 1.5 times
of rating
pressure
-
Maximum excitation current 3.0 mADC
Operating temperature -20~100 °C
Storage temperature -40~120 °C
Operating humidity 30~80(Non dew condition) %RH
Electric characteristics (Drive Current 1.5mA constant, ambient temperature Ta=25°C)
Output span voltage 60~140(at 0kPa~rated pressure) mV
Offset voltage ±20(at 0kPa) mV
Bridge resistance 4000~6000 Ω
Response time 2(for the reference) msec
Accuracy TSO* ±5 %FS/
0~50°C
TCS* 2.5
Linearity ±0.5 ±0.3 ±0.5 ±0.6 %FS
Pressure hysteresis ±0.4 ±0.2 ±0.4 %FS
*TSO:Temperature sensitivity of offset voltage
*TCS:Temperature coefficient of output span voltage
*Temperature range from 0-50 deg C
Contact us here for inquiries.