XFPM Series(Gauge)

 

Features
  • On-chip amplification and temperature compensations
    Pre-calibration of offset voltage and span
    Dual-in-line package(DIP)
  • Weight : 1.2grams

RoHS compliance

Ordering Information

 

Measurable pressure range(kPa) Part number
-100~100 XFPM-100KPGW XFPM-100KPGWR
0~-100 XFPM-100KPGV XFPM-100KPGVR
0~25 XFPM-025KPG XFPM-025KPGR
0~50 XFPM-050KPG XFPM-050KPGR
0~100 XFPM-100KPG XFPM-100KPGR
0~200 XFPM-200KPG XFPM-200KPGR
0~1000 XFPM-001MPG XFPM-001MPGR
Specifications
Model 100KPGW 100KPGV 025KPG 050KPG 100KPG 200KPG 001MPG Unit
Recommended operating conditions
Pressure type Gauge pressure -
Rated pressure ±100 -100 25 50 100 200 1000 kPa
Measurable pressure range -100~100 0~-100 0~25 0~50 0~100 0~200 0~1000 kPa
Temperature range 0~85 °C
Pressure media Non-corrosive gases only(No liquid) -
Supply voltage(constant) 5±0.25 VDC
Absolute maximum rating
Maximum load pressure Twice of rated pressure 1.5 times
of rating
pressure
-
Maximum excitation voltage 8 VDC
Operating temperature -40~125 °C
Storage temperature -40~125 °C
Operating humidity 30~80(Non dew condition) %RH
Electrical characteristics(Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25°C)
Power consumption 10mA max. mA
Output impedance 10Ω max. Ω
Source current 0.2mA max. mA
Sink current 2mA max. mA
Response time 2(for the reference) msec
Output span voltage 4.5 V
Offset voltage *1 *2 *3 0.2±0.1125(at 0kPa) V
Output voltage at full scale *1 *4 *5 4.7±0.1125(at rated pressure) V
Accuracy *1 ±2.5 %FS/
0~85°C
*1  Excluding input voltage error.
*2  0.2±0.1125V(at -100kPa)  *3  0.2±0.1125V(at 0kPa)
*4  4.7±0.1125V(at +100kPa)  *5  4.7±0.1125V(at -100kPa)
Others

Data sheet[PDF444KB]

Distributors

Contact Us