| Model |
03PGV |
100KPGV |
025KPG |
050KPG |
100KPG |
200KPG |
Unit |
| Recommended operating conditions |
| Pressure type |
Gauge pressure |
- |
| Rated pressure |
-24.5 |
-100 |
25 |
50 |
100 |
200 |
kPa |
| Measurable pressure range |
0~-24.5 |
0~-100 |
0~25 |
0~50 |
0~100 |
0~200 |
kPa |
| Temperature range |
0~50 |
°C |
| Pressure media |
Non-corrosive gases only(No liquid) |
- |
| Supply voltage(constant) |
5±0.25 |
VDC |
| Absolute maximum rating |
| Maximum load pressure |
Twice of rated pressure |
- |
| Maximum excitation voltage |
8 |
VDC |
| Operating temperature |
-10~80 |
°C |
| Storage temperature |
-20~100 |
°C |
| Operating humidity |
30~80(Non dew condition) |
%RH |
| Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25°C) |
| Power consumption |
10mA max. |
mA |
| Output impedance |
10Ω max. |
Ω |
| Source current |
0.2mA max. |
mA |
| Sink current |
2mA max. |
mA |
| Response time |
2(for the reference) |
msec |
| Output span voltage |
4.0 |
V |
| Offset voltage * |
0.5V(at 0kPa) +/-0.1V(25deg.C) , +/-0.2V(0 to 50deg.C) |
V |
| Output voltage at full scale * |
4.5V(at rated pressure) +/-0.1V(25deg.C) , +/-0.2V(0 to 50deg.C) |
V |
| Accuracy * |
±5.0 |
%FS/0~50°C |