Data Collection

Environmental load data of each site

←:same as left
<:less than

Fujikura Sakura Works

Constituent of Atmosphere
Items Object Equipment Regulation Value Voluntary Standard Value Result
NOx (ppm) Gas Fired Boiler 150 100 68
Gas Generation Furnace, Heating Furnace 150 100 13
SOx (m3N/h) Gas Fired Boiler K-value Regulation 1.3 K-value Regulation 1.3 0
Gas Generation Furnace, Heating Furnace K-value Regulation 1.7 K-value Regulation 1.7 0
Dust and Soot (g/m3N) Gas Fired Boiler 0.1 0.01 <0.001
Gas Generation Furnace, Heating Furnace 0.1 0.01 0.001
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Results
Potential Hydrogen (pH) 5.8~8.6 Min 7.4 Max7.7
Biochemical Oxygen Demand (BOD) (mg/l) 25 10 2.1
Chemical Oxygen Demand (COD) (mg/l) 25 20 2.9
Suspended Solid (SS) (mg/l) 50 20 2
Normalhexane Extracts (Mineral Oil) (mg/) 3 1.5 <1
Phenolic Compounds (mg/l) 0.5 0.25 <0.005
Copper content (mg/l) 1 0.5 <0.005
Zink Content (mg/l) 2 1.5 0.64
Dissolved Iron Content (mg/l) 5 2.5 0.17
Dissolved Manganese Content (mg/l) 5 2.5 0.15
Fluorine Content (mg/l) 8 4 1.0
Boron Content (mg/l) 10 5 0.029
Chrome Content (mg/l) 1 0.5 <0.005
Number of Colitis Germ Legions (No./cm3) 3,000 1,000 75
Nitrogen Content (mg/l) 20 10 4.4
Phosphorus Content (mg/l) 3 0.32

Fujikura Suzuka Works

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Results
Potential Hydrogen (pH) 5.8~8.6 6.2~8.0 Min 7.1
Max 7.5
Biochemical Oxygen Demand (BOD) (mg/l) 160 25 8.0
Chemical Oxygen Demand (COD) (mg/l) 160 15 6.0
Suspended Solid (SS) (mg/l) 200 30 6.0
Normal hexane Extracts (Mineral Oil) (mg/) 5 3 0
Normal hexane Extracts (Animal and Vegetable Oils) (mg/l) 30
Number of Colitis Germ Legions (No./cm3) 3000 450
Nitrogen Content (mg/l) 120 10 5.5
Phosphorus Content (mg/l) 16 5 0.33

Fujikura Numazu Works

Constituent of Atmosphere
Items Object Equipment Regulation Value Voluntary Standard Value Results
NOx (ppm) Boiler 100 72
Dust and Soot (g/m3N) Boiler 0.05 0.007
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Results
Potential Hydrogen (pH) 5.8~8.6 6.8~8.2 Min 6.9 Max 8.2
Biochemical Oxygen Demand (BOD) (mg/l) Av 5 Max 10 Av 1.4 Max 2.5
Suspended Solid (SS) (mg/l) Av 7 Max 13 Av 1.1 Max 2
Normal hexane Extracts (Mineral Oil) (mg/l) Av 2 Max 5 <2
Copper Content (mg/l) 0.2 0.01
Iead Content (mg/l) 0.01 <0.01
Dissolved Iron Content (mg/l) 10 7 0.24
Number of Colitis Germ Legions (No./cm3) 3000 52

Fujikura Ishioka Works

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 6.0~8.4 Min 6.66 Max 7.09
Biochemical Oxygen Demand (BOD) (mg/l) 25 23 51*1
Suspended Solid (SS)(mg/l) 40 38 4.3
Normal hexane Extracts
(Mineral Oil) (mg/l)
3 2 <1.0
Nitrogen Content (mg/l) 45 32 45.7*2
Phosphorus Content (mg/l) 6 5 2.2

*1 Under measures examination.
*2 After counter measures, the results became within the regulation value.

Numazu Copper Refining and Rolling Co.,Ltd.

Constituent of Atmosphere
Items Object Equipment Regulation Value Voluntary Standard Value Result
NOx (ppm) Dust Chamber for Shaft Kiln 200 70 29
SOx (m3N/h) Dust Chamber for Shaft Kiln 11.2 6.4 <0.04
Dust and Soot (g/m3N) Dust Chamber for Shaft Kiln 0.2 0.01 0.015*

* After counter measures ,the results became within the Voluntary Standard value.

Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 6.5~8.0 Min 6.4 Max 7.4*
Biochemical Oxygen Demand (BOD) (mg/l) 25 10 4.9
Chemical Oxygen Demand (COD) (mg/l) 160 10 4.9
Suspended Solid (SS) (mg/l) 60 10 5.0
Normal hexane Extracts
(Mineral Oil) (mg/l)
5 1 <1.0
Copper Content (mg/l) 1 0.8 0.5

* After counter measures ,the results became within the Voluntary Standard value

Aomori Fujikura Kanaya Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 7.8
Biochemical Oxygen Demand (BOD) (mg/l) 160 (daily average 120) 80 (daily average 60) 2.4
Chemical Oxygen Demand (COD) (mg/l) 160 (daily average 120) 80 (daily average 60 2.9
Suspended Solid (SS) (mg/l) 200 (daily average 150) 100 (daily average 75) 1
Normal hexane Extracts (Mineral Oil) (mg/l) 5 2.5 <0.5
Normal hexane Extracts (Animal and Vegetable Oil) (mg/l) 30 15 <0.5
phenolic Compounds (mg/l) 5 2.5 <0.02
Copper Content (mg/l) 3 1.5 <0.01
Zink Content (mg/l) 5 2.5 <0.02
Dissolved Iron Content (mg/l) 10 5 0.023
Dissolved Manganese Content (mg/l) 10 5 <0.01
Chrome Content (mg/l) 2 1 <0.02
Number of Colitis Germ Legions (No./cm3) daily average 3000 daily average 1500 24
Nitrogen Content (mg/l) 120 (daily average 60 60 (daily average 30) 1.5
Phosphorus Content (mg/l) 16 (daily average 8) 8 (daily average 4) 0.26

Shinshiro Cable Co.,Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 Min 7.1 Max 7.9
Biochemical Oxygen Demand (BOD) (mg/l) 20 1.8
Chemical Oxygen Demand (COD) (mg/l) 20 4.2
Suspended Solid (SS) (mg/l) 20 2.8
Normal hexane Extracts (Mineral Oil) (mg/l) 2 <0.5
Normal hexane Extracts (Animal and Vegetable Oil) (mg/l) 10 <0.5
phenolic Compounds (mg/l) 0.5 <0.025
Copper Content (mg/l) 1 0.01
Zink Content (mg/l) 2 0.08
Dissolved Iron Content (mg/l) 10 <0.1
Dissolved Manganese Content (mg/l) 10 <0.1
Fluorine Content (mg/l) 8 <0.1
Chrome Content (mg/l) 2 <0.04
Number of Colitis Germ Legions(No./cm3) 3000 280

DDK Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 6.0~8.4 Min 7.4 Max 7.7
Biochemical Oxygen Demand (BOD) (mg/l) 25 (daily average 20) 20 13
Suspended Solid (SS) (mg/l) 50 (daily average 40) 26 7
Normal hexane Extracts (Mineral Oil) (mg/l) 5 Sum 5 <1
Normal hexane Extracts (Animal and Vegetable Oil) (mg/l) 10
Copper Content (mg/l) 3 1 <0.05
Zink Content (mg/l) 2 1 <0.05
Dissolved Iron Content (mg/l) 3 1 <0.05
Dissolved Manganese Content (mg/l) 3 0.1 <0.01
Fluorine Content (mg/l) 8 5 <0.2
Boron Content (mg/l) 10 0.5
Chrome Content (mg/l) 2 0.1 <0.02
Number of Colitis Germ Legions(No./cm3) 3000 1500 40

Tohoku Fujikura Ltd.

Constituent of Atmosphere
Items Object Equipment Regulation Value Voluntary Standard Value Result
NOx (ppm) Boiler (1) 260 200 86
Boiler (2) 77
Boiler (3) 76
Boiler (4) 76
SOx (Nm3N/h) Boiler (1) 0.391 0.100 <0.005
Boiler (2) 0.395 <0.005
Boiler (3) 0.316 <0.003
Boiler (4) 0.316 <0.003
Dust and Soot (g/m3N) Boiler (1) 0.3 0.05 <0.01
Boiler (2) 0.3 <0.01
Boiler (3) 0.3 <0.01
Boiler (4) 0.3 <0.01
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 6.2~7.8 6.7
Biochemical Oxygen Demand (BOD) (mg/l) 30 6.9
Chemical Oxygen Demand (COD) (mg/l) 30 5.1
Suspended Solid (SS) (mg/l) 70 17
Normal hexane Extracts (Mineral Oil) (mg/l) 5 <1
phenolic Compounds (mg/l) 0.5 <0.1
Copper Content (mg/l) 1 <0.01
Zink Content (mg/l) 2 0.04
Dissolved Iron Content (mg/l) 10 0.03
Dissolved Manganese Content (mg/l) 10 0.03
Fluorine Content (mg/l) 8 0.1
Boron Content (mg/l) 10 0.1
Chrome Content (mg/l) 2 <0.05
Number of Colitis Germ Legions (No./cm3) 3000 210
Nitrogen Content (mg/l) 20 2.6
Phosphorus Content (mg/l) 2 0.11

Nishi Nippon Electric Wire & Cable Co.,Ltd.

Constituent of Atmosphere
Items Object Equipment Regulation Value Voluntary Standard Value Result
NOx (ppm) Boiler 180 60
SOx (m3N/h) Boiler 0.8 <0.007
Dust and Soot (g/m3N) Boiler 0.3 <0.02
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.0~9.0 5.5~8.5 Min 6.9 Max 8.0
Chemical Oxygen Demand (COD) (mg/l) 15 (daily average 10) daily average 9.8 7.2
Suspended Solid (SS) (mg/l) 30 (daily average 20) 20 9.3
Normal hexane Extracts (Mineral Oil) (mg/l) 2 <1
Normal hexane Extracts (Animal and Vegetable Oil) (mg/l) 2 <1
phenolic Compounds (mg/l) 5 <0.1
Copper Content (mg/l) 3 0.02
Zink Content (mg/l) 2 0.038
Dissolved Iron Content (mg/l) 10 <0.05
Dissolved Manganese Content (mg/l) 10 <0.02
Fluorine Content (mg/l) 8 0.1
Chrome Content (mg/l) 2 <0.02
Number of Colitis Germ Legions (No./cm3) 3000 25
Nitrogen Content (mg/l) 25 1.97
Phosphorus Content (mg/l) 3 0.6

Nishi Nippon Electric Wire & Cable Co.,Ltd. (Hasama)

Constituent of Atmosphere
No Equipment
Living environment Items Regulation Value Voluntary Standard Value Result
Water Quality Analysis
Potential Hydrogen (pH) 5.8~8.6 6.7
Biochemical Oxygen Demand (BOD) (mg/l) 25 (daily average 20) 7.1
Suspended Solid (SS) (mg/l) 40 (daily average 30) 8.8
Normal hexane Extracts (Animal and Vegetable Oil) (mg/l) 7 <0.5
Number of Colitis Germ Legions (No./cm3) 3000 0

Fujikura Automotive Asia Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 6.1~8.6 Min 6.7 Max 7.3
Biochemical Oxygen Demand (BOD) (mg/l) 25 20 24.5
Suspended Solid (SS) (mg/l) 60 50 14
Normal hexane Extracts (Mineral Oil) (mg/l) 5 4 2.2
Fluorine Content (mg/l) 8 <0.2
Boron Content (mg/l) 10 0.4
Number of Colitis Germ Legions (No./cm3) 3000 1,646

Fujikura Automotive Asia Ltd. (Hachimanpara)

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Normal hexane Extracts (Mineral Oil) (mg/l) 5 <0.5
Normal hexane Extracts (Animal and Vegetable Oil) (mg/l) 30 <0.5

Yonezawa Electric Wire Co.,Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.8~8.6 8.1
Biochemical Oxygen Demand (BOD) (mg/l) daily average 20 25*
Suspended Solid (SS) (mg/l) daily average 50 2
Normal hexane Extracts (Mineral Oil) (mg/l) 10 <1
phenolic Compounds (mg/l) 1 1.4*
Copper Content (mg/l) 2 <0.05
Zink Content (mg/l) 2 <0.05
Dissolved Iron Content (mg/l) 10 0.19
Dissolved Manganese Content (mg/l) 10 0.07
Chrome Content (mg/l) 2 <0.05
Number of Colitis Germ Legions (No./cm3) daily average 3000 0
Nitrogen Content (mg/l) daily average 60 0.2
Phosphorus Content (mg/l) daily average 8 0.17

* After counter measures, the results became within the regulation value.

Fujikura Precision Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard ValueVoluntary Result
Potential Hydrogen (pH) 5.8~8.6 8
Biochemical Oxygen Demand (BOD) (mg/l) 600 82
Suspended Solid (SS) (mg/l) 600 29
Normal hexane Extracts (Mineral Oil) (mg/l) 5 2.2
Nitrogen Content (mg/l) 240 25
Phosphorus Content (mg/l) 32 2.1

Suzuki Giken Co.,Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.0~9.0 Min 6.7 Max 8.5
Suspended Solid (SS) (mg/l) 600 340
Normal hexane Extracts
(Animal and Vegetable Oil) (mg/l)
30 23
Copper content(mg/l) 1 <0.05
Zink Content(mg/l) 2 0.09

Fujikura Solutions Ltd.

Constituent of Atmosphere
No Equipment
Water Quality Analysis
Living environment Items Regulation Value Voluntary Standard Value Result
Potential Hydrogen (pH) 5.0~9.0 5.0~8.0 Min 7.0 Max 7.7